Transformer for TOUAREG,PORSCHE and BENTLEY instrument cluster illumination repair
Minimum order: 10 pieces.
TOUAREG,PORSCHE and BENTLEY owner have many problems with this car instrument cluster.The problems include no lighting,partial lighting and /or flickering or intermittent lighting,or cann’t see the miles badly .Mainly to repair this dashboard you need replace defective lighting transformer to a new one.
Type A: For BOSCH high voltage transformer 8 903 428 016 ,used in Mercedes S Class W220 care year 1998-2000 (dashboards with 93C66 EEPROM inside).
Type B: For BOSCH high voltage transformer 9 948 411 098, 9 948 411 025, 9 948 411 09 027. For Mercedes S Class W220 cars year 2000-2005 (dashboards with 24c04 EEPROM inside).
Transformer (VOGT) for Mercedes Benz S Class W220
Information: Mercedes Benz S Class W220 owner have many problems with this car instrument cluster. The problems include no lighting, partial lighting and /or flickering or intermittent lighting, or cant see the miles badly. Mainly to repair this dashboard you need replace defective lighting transformer to a new one
Products: We have two types of them: Type A: For BOSCH high voltage transformer 8 903 428 016 ,used in Mercedes S Class W220 care year 1998-2000 (dashboards with 93C66 EEPROM inside). Type B: For BOSCH high voltage transformer 9 948 411 098, 9 948 411 025, 9 948 411 09 027. For Mercedes S Class W220 cars year 2000-2005 (dashboards with 24c04 EEPROM inside).
No-load transformer capacity loading and comprehensive analysis tester 1) Functions, features and use A. Single machine can complete under 1000kVA distribution transformers and full-electric flow load test; About a third of the rated power flow can be completed under 2500kVA distribution transformers load test(About a third of the rated flow, electric instrument can be converted to the rated flow load loss electric parameters). B. Single machine can complete under 6300kVA distribution transformer capacity experiment and capacity test. Self-contained test power can charge 100 sets of 2500kVA distribution transformer capacity test in one time. According to the experiment results, transformer no-load loss can judge the transformer models. C. 240 * 120 large blue LCD, Chinese operation menu, high-speed printers print test results, and the historical record. D. With high-performance processor as the core of control and operation. Sampling speed. The data stability is satisfactory. E. It can external voltage transformer and current transformer can broaden instrument measurement range. F. Current, voltage transformer, sampling don\'t pass through mutual inductor but take samples directly, greatly improved instrument measurement range and accuracy of measurement, better than most of the similar instruments in the market. G. They are small, light and easy to carry, and are suitable for laboratory and field test and operation procedures. H. HRKFR transformer no-load loading and capacity of comprehensive analysis instrument is according to JB/T501-91(Power Transformer Test Guidelines) and GB1094-96 <Power Transformer>. 2) The main technical indexes A. Test items a) Three-phase RMS: Uab、Ubc、Uca; b) Three-phase average voltage: /Uab、/Ubc、/Uca; c) Three-phase current: I a、I b、I c; d) No-load loss and no-load current percentage: Pm、Io%; e) Load loss, impedance voltage percentage and short-circuit impedance: Pkt、ekt、Zt; f) The capacity of transformer. B. Main Technical specifications a) Empty load current measurement range:0.1A ~ 60A,measuring precision 0.2 level; b) Voltage measurement range:10V ~ 500V,measuring precision 0.2 level; c) Plus transformer can widen instrument measurement range: 10kV、100mA~200A; d) Frequency measurement range: 45 ~ 65Hz,measuring precision 0.1 level; e) The power input: AC220V±10%; f) Conditions of use: degree of wetness﹤95%RH,temperature-10℃~45 8451;; g) Use and storage site should be no serious influence of gas, steam, insulation resistance.it dust and it explosive and corrosive medium.
smart Transformer calibration Features Display mode: Chinese large LCD Storage function: PT, CT scan data every 40 group, On CT 1% of the error data storage point, Automatic measurement: Can automatic measurement, according to defined procedures for S level transformer automatic measurement, Online functions: With H - H calibration platform and HDH software interface; Printing function: real-time or inquires the print, Polarity judgment: Automatic judgment polarity, effectively guarantee personal safety and instrument. Technical parameters Measuring object: PT、CT、Y、Z Working scope: Current 1 ~ 149% (note: can school S level transformer voltage 5 ~ 149% Measuring scope: a) In-phase component (%) : 0.0001 ~ 19.99 resolution: 0.0001 b) Quadrature component (points) : 0.001 ~ 600nm resolution: 0.001 c) Friction resistance (Ω) : 0.0001 ~ 5.99 for resolution: 0.0001 d) Guide na (mS) : 0.0001 ~ 5.99 for resolution: 0.0001
series of current and voltage type transformer load cases Features Light weight, beautiful appearance, large capacity, with good stability. (special request extensible) Technical parameters Environmental conditions: wen degrees: 5 ℃ ~ 40 ℃ wet degrees: < 80% (25 ℃). The sea pull: < 3000m power frequency: 50Hz The rated capacity: voltage 1.25 VA ~ 157.5 VA, Current 2.5 VA ~ 80VA Measuring scope: voltage 20% ~ 120%, Current 1% ~ 120% Secondary voltage: voltage phase failure is 100V, current 5A Power factor: 0.8, 1 Accurate analytical accuracy: 3% + 0.05 VA Test voltage: 2kV