Residual Current Operated Circuit Breaker (02/06/2006)
LEL11 (electromagnetic) residual current operated circuit breaker is used for protection against electrical leakage in the circuit of 50Hz or 60Hz with rated voltage of 230V and rated current up to 40A. This electromagnetic RCBO can protect the circuit against overload and short circuit or for unfrequented switchover under normal conditions. It can be applied to domestic and similar places as main switch.
[Related Categories: Circuit Breakers ]
[Related Keywords: residual, current, operated, circuit, breaker ]
Portable Residual Current Device (Britain) (10/30/2005)
Features: 1) RCD-adapter for personal protection tested according to DIN VDE 0661 EN61540 2) Increased safety without change of installation 3) For electric devices in the bathroom, kitchen, workshop, garden and laboratories 4) Effective personal protection due to low nominal release current of 30mA (fault current) 5) Very short cutout time (20ms) 6) Cutout of 2 poles (L+N) 7) Pulse current sensitive 8) Low voltage release 9) Suitable for a temperature range of -25°C to +40°C 10) Enclosure type IP 40 and IP44 Certification(s): CE
[Related Categories: Circuit Breakers ]
[Related Keywords: portable, residual, current, device, britain ]
Residual Current Circuit Breaker (12/23/2005)
Specifications: The rccb conform to international gb16916, iec1008, bs4293 standards. They are Used in the circuits of AC 50-60hz, single phase 240v(220v), three phase 415v(380v) Products in industrial and mining enterprises, commercial buildingsand housing. It provides protection from electric shock hazards and for infrequent Switchover of circuits under normal conditions. Main technical parameter Rated current:16,25,32,40,63,80,100a Rated operating current:0.03,0.1,0.3,0.5a Rated voltage: AC 230~415v Pole number:2p,4p Breaking capacity:3000 to 6000a Type: AC, AC & dc(a type)
[Related Categories: Circuit Breakers ]
[Related Keywords: residual, current, circuit, breaker ]
Residual Current Circirt Breaker (02/08/2006)
Specifications: Application 3SL36 provides ground fault protection by monitoring the leakage of current to ground. The 3SL36 will trip when ground faults are detected in excess of the GF trip rating of the RCCB. The product can also detect and trip when there is a current Differential between the live line and neutral line, and therefore protect people from electric shock. These devices provide GF protection and life protection And are used in series with standard MCBs which provide overload and short circuit protection. The 3SL36 can be used as a main device providing GF and life protection for several MCB branch devices. The product is fully tested in strict compliance with The requirement of IEC61008. WE ARE MANUFACTURING ALL KINDS OF RCCB, SEE WEBSITES BELOW FOR MORE DETAILS
[Related Categories: Circuit Breakers ]
[Related Keywords: residual, current, Circirt, breaker ]
Residual Current Circuit Breaker (08/19/2006)
Specifications: (rcbo) conforms to the standards GB 16917.1997, IEC 1009-1 etc. It is used in the circuits of ac50-60hz, single phase 230v(220v), rated current 10a-40a for prot-ecting personal from electric shock hazard, also can be used for protecting power Line & electric equipment(e. G. Motor)from overload and short circle. It can cut offthe fault circuit immediately on the occasion of shock hazard or earth leakage of trunk line. Fcl5 rcbo is mainly suitable for use in varieties of plants, & enterprises, buildings, commerce construction, hotels, home and so on.
[Related Categories: Circuit Breakers ]
[Related Keywords: residual, current, circuit, breaker ]
Residual Current Circuit Breaker (08/27/2006)
Specifications: RCCB Series Voltage:220-400V Law's
[Related Categories: Circuit Breakers ]
[Related Keywords: residual, current, circuit, breaker ]
residual current circuit breaker (03/01/2005)
Specifications: The item is in accordance with standards of VDE 0664,IEC1008 and BS4293 etc,applyingto the circuit of AC50/60Hz,240V single phase,415V three phases and below itfor industrial and mining enterprise,building trade,commerce and family.To mainlyprevent electric fire and personal casualty accideng caused by personal electricshock or leakage of electrified wire netting,this RCCB is a cuurent-operated,fastleakage protector of pure electromagnetic type,which can break off fault circuitrapidly in order to avoid occurrence of accident.The item is precise in structure,lesselements,withoutauxiliary power and high working reliablility.Thefunction of the swith won`t be in fluenced by ambient temperature and lightning.Themutual inductor of the item is used to test vector differential value of passingcurrent,and produces are levant output power and add it differential valueof protected circuit of personal electric shock is up to or over leakage operratingcurrent,the tripper will act and cut off,so that the item will take effect ofprotection.GROW
[Related Categories: Circuit Breakers ]
[Related Keywords: residual, current, circuit, breaker ]
Residual Circuit Device (03/14/2006)
Specifications: CDM7 molded case circuit breakers are designed for non-frequent making and breaking operations under normal conditions in power distribution networks. International standards: IEC 60947-1 Low-voltage switchgear and control gear - General IEC 60947-2 Low-voltage switchgear and control gear - Low-voltage circuit breaker National standards: GB/T 14048.1 Low-voltage switchgear and control gear - General GB 14048.2 Low-voltage switchgear and control gear - Low-voltage circuit breakerDELIXI Payment Terms: L/C,T/T,CASH,D/P Certification(s): KEMA
[Related Categories: Circuit Breakers ]
[Related Keywords: residual, circuit, device ]
Residual Current Device(RCD) (02/07/2006)
Specifications: RCD F360: 2P, 4P technical docs. availabe when claimed.
[Related Categories: Circuit Breakers ]
[Related Keywords: residual, current, device, RCD ]
Residual Current Devices (01/15/2006)
Specifications: Residual Current Devices briefly RCDs, are designed for protection of humans andanimals against the dangerous effects of electric current. When parts under voltageare touched, the RCD instantly switches off the current long before any amountor duration of current flow can cause damage. Such fields of application are, e.g., rooms with bath tubs or shower, saunas, indoorand outdoor swimming pools, farming facilities, outdoor sockets, etc.
[Related Categories: Circuit Breakers ]
[Related Keywords: residual, current, devices ]
1 2 3 4 5 6 7

Home | Sell Offers | Buy Offers | Products | Companies | Member Area | Contact us | Partner | Directory | Banner | Terms | About us
Hot Products: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z
Hot Companies: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z
Copyright Notice © 2008 tradenote.net Corporation and its licensors
All rights reserved. - Import Export Business